Bottom of Pipe vs Bottom of Insulation Tags
I would like to be able to place an elevation tag that knows if there is insulation or not and place the correct tag accordingly. If the pipe has insulation, it would place our BOI tag. If it has no insulation, it would place our BOP tag.
Comments: 2
Oldest
•
Newest
•
Most likes
•
Fewest likes
-
27 Dec, '22
AngelaHighlighted comment
same with ductwork. bod should be bottom of duct - not bottom of insulation - on duct AND fittings. -
17 May, '24
Michael JohnsonWould there be a way to add these parameters to the MEP Fabrication Hanger category as well? We know that the hanger has the parameter Middle Elevation, which is the elevation at which either the bottom of insulation or pipe touches the hanger. If eM_Insulation Thickness is acquired during the hanger placement, this could be a formula that would be Bottom of Pipe = Middle Elevation + eM_Insulation Thickness. If I could schedule this parameter, the field personnel wouldn't need to know the insulation values to set hangers for pipe, especially when the insulation contractor is not providing the Calcium Silicate blocks for the hangers.